共找到 1205 條與 帶絕緣層電線 相關(guān)的標(biāo)準(zhǔn),共 81 頁
Specifications for particular types of winding wires -- Part 48: Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire, temperature index 155
Specifications for particular types of winding wires -- Part 0-6: General requirements -- Glass-fibre wound resin or varnish impregnated, bare or enamelled round copper wire
Specifications for particular types of winding wires -- Part 32: Glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 155
This part of IEC 60317 specifies the requirements of enamelled rectangular aluminium winding wire of class 105 with a sole coating based on polyvinyl acetal resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance of application characteristics. Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317-0-9.
Specifications for particular types of winding wires - Part 67: Polyvinyl acetal enamelled rectangular aluminium wire, class 105
This part of IEC 60317 specifies the requirements of enamelled rectangular aluminium winding wire of class 220 with a dual coating. The underlying coating is based on polyester or polyesterimide resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements. The superimposed coating is based on polyamide-imide resin. NOTE A modified resin is a resin that has undergone a chemical change, or contains one or more additives to enhance certain performance of application characteristics. Wires of grade 1 and grade 2 are included in this part of IEC 60317 and apply to the complete range of conductors. The specified combinations of width and thickness as well as the specific ratio width/thickness are given in IEC 60317-0-9.
Specifications for particular types of winding wires - Part 69: Polyester or polyesterimide overcoated with polyamide-imide enamelled rectangular aluminium wire, class 220
35kV and below solid insulated tubular bus
Winding wires. Test methods. Chemical properties
UL Standard for Safety Single- and Multi-Layer Insulated Winding Wire (Third Edition)
Sintered electromagnetic wire for wind turbine generators Part 2: Test methods
Sintered electromagnetic wire for wind turbine generators Part 1: Technical conditions
Specifications for particular types of winding wires - Part 31: Glass fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 180 (IEC 60317-31:2015); German version EN 60317-31:2016
Specifications for particular types of winding wires - Part 39: Glass-fibre braided resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 180 (IEC 60317-39:2015); German version EN 60317-39:2016
Specifications for particular types of winding wires - Part 33: Glass fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 200 (IEC 60317-33:2015); German version EN 60317-33:2016
Specifications for particular types of winding wires - Part 32: Glass fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire, temperature index 155 (IEC 60317-32:2015); German version EN 60317-32:2016
Specifications for particular types of winding wires - Part 0-4: General requirements - Glass-fibre wound, resin or varnish impregnated, bare or enamelled rectangular copper wire (IEC 60317-0-4:2015); German version EN 60317-0-4:2016
Winding wires - Test methods - Part 2: Determination of dimensions (IEC 60851-2:2009 + A1:2015); German version EN 60851-2:2009 + A1:2015
Rated voltage 1kV and below Steel core aluminum stranded core XLPE insulated overhead cable
Rated voltage 0.6/1kV (Um=1.2kV) flame-retardant and fire-resistant 125℃ irradiated XLPE insulated low-smoke halogen-free power cable
Rated voltage 10kV steel conductor aluminum stranded conductor XLPE insulated overhead cable